305
Cut-out in rear panel for non-ducted recirculation (Plug&Play installation)
Where possible, make use of the drilling template included with the appliance in its original size. If you do not have the drilling template to
hand, please follow the following instructions:
Flush-fit installation:
Image of drilling template, side 1. Not shown to scale.
• Measure the thickness of the worktop (C).
• Locate the centre of the long axis of the cut-out.
• Mark the point 183 mm to the right of the centre (A).
• Mark the point (D) below the right-hand end of line A (121.5 mm - C (worktop thickness)).
• Saw a hole with a diameter of 146–150 mm around this point.
• Connect the Plug&Play adapter in position 1.
22-1557_Part20_Skizzen_VitroLine_Gen7000_Kurz_GB.indd 305
22-1557_Part20_Skizzen_VitroLine_Gen7000_Kurz_GB.indd 305
16.03.23 14:00