457
Emergency
Emergency
25,5
51,5
156
65
33
198
Emergency light kit | Emergency
range
output
input
PF
KIT0014
Universal C.C.
9-57V 350-60mA
220~240V AC
0.5
Universal C.V.
24V 2000mA
Frequency
50-60 Hz
Nominal input current
20 mA
Outout voltage (without load)
9-57V C.C. / 24V C.V.
TA Operating temperature
0 +50 °C
Max casing temperature TC
70 °C
Control interface
Switch Line, Rest mode
Protections
Overtemperature, overload, overvoltage,
short-circuit, open circus
Emergency output current
350-60 mA C.C. / 2000mA C.V.
Emergency power
3,4W
Recharging time
24 h
Reference norms
EN61347-2-13, EN61347-2-7, EN61547, EN55015,
EN60598-2-22, EN61000-3-2
1
1
3
5
BATT.
ON
2
2
4
6
LED indicator
Indicatore LED
-
+
-
-
+
+
L
VIN
LED
OUT
LED
Driver *
N
L
L
PWR
IN
+- REST
MODE
CHARGE
220/240V
50/60Hz
N
N
LED
SOURCE
The installation of the emergency kit is
quick and simple: the Emergency unit only
needs to be connected to the LED driver
as shown in the diagram.
*the driver is not included in the
Emergency kit/the Emergency kit can be
connected to all the original drivers of the
LED device.
- Maintained or non maintained operation
- Suitable for electronic driver, dimmable electronic driver
- Adjustable version dip-switch, constant current or constant
voltage to power LED to LED modules
- Connected to power supplies with maximum output voltage
and current 90V and 2A
- Automatic operation
- High temperature NiCd batteries
- Charge indicator with FROR led cable
- Protection device against extensive discharge
- MAT4 DALI self diagnosis system with external module
- Charging device with supply is reinforced insulation able to
recharge the battery normally after the test in clause 22.3 of
the IEC 61347-2-7:2007.
- Supplied with 3,000 mAh battery pack.