65
Projectors & Suspensions
Operation
percentage
Power
output
Ambient
temperature
100 %
200 W
70 C°
90 %
184 W
73 C°
65 %
125 W
79 C°
60 %
100 W
90 C°
100 %
40 %
30 %
10 %
20 %
80 %
90 %
70 %
50 %
60 %
0 %
200 W
80 W
60 W
20 W
40 W
160 W
180 W
140 W
100 W
120 W
0 W
10 C°
20 C°
30 C°
40 C°
50 C°
60 C°
70 C°
80 C°
90 C°
100 C°
Power output
0
Ambient
temperature C°
17 Kg
51 dm³
Ø300
302
195
80
Ø240
575
6 LEDs - CRI 80
92793
RAL9006
W 3000 K
29905 lm
60 Flood*
N 4000 K
31570 lm
90 Wide Flood
C 5000 K
31931 lm
11 Wide Flood
88 Oval
Flamp HP | Suspension | 190-250 V | 187 W DC - 206 W AC arrayLED
1 m
70°C
Comfort
UGR≤22*
The photometric curves are available at www.linealight.com. On request, we carry out technical lighting calculations
to determine the number of items that will be satisfactory in order to guarantee the required lighting needs.
Operation of the fixture in relation
to the temperature of the surrounding environment
Different projector models for environments with high temperatures are available on request