240
INDUSTRIAL
Posts
Zn
RAL7035
RAL7016
Technical characteristics
The calculations with the relative design loads are carried out in accordance with:
• Presidential Decree 07/01/1956 No. 164 “Regulations for the prevention of injuries in the workplace.”
• Law No. 1086 of 05/11/71: “Regulations on works by reinforced, normal and prestressed concrete and in metallic structure.”
• CNR - UNI 10011/88: “Steel construction: instructions for calculation, execution, commissioning and maintenance.”
• CNR10022/84: “Cold formed sections. Instructions for use in building.”
• “UNI - ENV ” 1993-1-1(2004 - Eurocode 3, Design of concrete structures Part 1- 1: General regulations-General rules and rules for buildings.
• Ministerial Decree 14/01/08 Technical standards for construction.
• Ministerial Circular No. 617 of 02/02/09 “Instructions for the application of the Technical Standards for construction pursuant to Ministerial
Decree 14 January 2008.
• “UNI-ENV 1991-2-4 (1997), Eurocode 1, Basis of design and actions on structures” For the entire sector of posts 20 m tall or shorter
(straight posts) and equal to or shorter than 18 m (posts with arm), in the European Union, the harmonized UNI-EN standards are applied
correlated with the “European Directive Council of 21 December 1988 relative to the reconciliation of the legislative, Regulatory and
administrative provisions of the member States concerning construction products EEC 89/106.”
• The lamp towers are constructed in observance of DPR 547 “Standards for prevention of accidents” and DPR 459 “Regulation for the
implementation of the 89/392/EEC, 91/368/EEC, 93/44/EEC and 93/68/ directives.
• EEC concerning the reconciliation of legislation by the member States relative to machines.
Finishes
• Hot galvanising by immersion in melted zinc bath.
• Processing carried out in accordance with UNI EN 40/4 standards.
• Powder coating.
• Hydrocarbonising of the external buried part.
• Anti-corrosion sleeve to the section of coupling in membrane.
ON REQUEST:
• On request, different colouring from the unified RAL range.
Processing
• Post top street lamp connecting shaft.
• Slot for terminal block.
• Incoming cables slot.
• Earth connection.
ON REQUEST:
• Base plate with anchoring holes.
• Reinforcing sleeve in welded steel.
MATERIAL
UNI EN 40/2 DIMENSIONAL TOLERANCES
PROTECTION
TAPERED AND
CYLINDRICAL POSTS
Steel: S235 JRH - UNI EN 10219 (Fe 360B)
External diameter: ± 1 %
Hot galvanising in accordance with
UNI EN ISO 1461
R: 360 - 490 N/mm²
Thickness: ± 10 %
R and H: 235 N/mm²
Straightness: ± 0.3 % of the total length
A: 20 %
Length: ± 0.5 %
CONICAL POSTS,
CURVED BY SHEET METAL
Steel: S235 JRH - UNI EN 10219 (Fe 360B)
External diameter: ± 1 %
Hot galvanising in accordance with
UNI EN ISO 1461
R: 360 - 490 N/mm²
Shape: ± 3 % from the diameter
R and H: 235 N/mm²
Thickness: ± 10 %
A: 20 %
Straightness: ± 0.3 % of the total length
Length: ± 0.5 %
TAPERED AND CONICAL
POSTS,
HOT ROLLED
Steel: S275 JOH - UNI EN 10219 (Fe 340) -
(S235 JOH - UNI EN 10219 on request)
External diameter: ± 3 %
Hot galvanising in accordance with
UNI EN ISO 1461
R: 410 - 560 N/mm²
(360 - 490 N/mm² on request)
Thickness: ± 0.3 %
R and H: 275 N/mm²
(360 - 490 N/mm² on request)
Straightness: ± 0.3 % of the total length
A: 20 %
Length: ± 50 mm
R = unit tensile strength load
R and H = unit yield load
A = elongation
The posts are made entirely
in galvanised steel.
The finishes represented here are indicative and may not
faithfully reproduce the final appearance of the product.