186
INDUSTRIAL
h 17:42
h 22:10
h 01:08
h 04:06
h 07:04
h 08:34
Autocontrol system
F1
600mA
F5
600mA
F2
500mA
F3
380mA
F4
250mA
midnight
00:00 h
“N”
night
morning
evening
h 20:48
h 21:47
h 01:11
h 02:56
h 04:41
h 05:35
F1
F5
F2
F3
F4
Night hours 08:47
Sunset h 20:48
Sunrise h 05:35
Duration
time slot
30%
of Night
20%
of Night
20%
of Night
20%
of Night
10%
of Night
Power exercised based
on the current used
100% =
600mA
80% =
500mA
60% =
380mA
40% =
250mA
100% =
600mA
Variation of the
brightness based on the
current
100%
84%
65%
46%
100%
Night hours 08:47
Sunset h 20:48
Sunrise h 05:35
autonomous lamp post head
The Autocontrol system makes it so that autonomous
street lights are able to automatically adjust the
luminous flow based on the selected programming
depending on the technical lighting needs. The system
works in combination with a timer or a twilight switch
upstream of the system which determines the daily
hours of operation.
Generally, the operating time is divided into 5 time
slots, proportional in percentage to the “N” duration of
the night. This time is stored by the power supply and
used to determine the hours of operation in the various
time slots of the following day.
Examples of operation
Dimming varies according to the season of the year
and latitude of the location. Below are two examples
of operation in periods of the year that differ in number
of night hours. With the Autocontrol system, a daily
energy savings can be achieved that varies between
20% and 25%.