174
INDUSTRIAL
N
N
L
L
L
N
L
Sw
PRI
SEC
Sw
Lin
Lout
Unswitch Switch
Test Switch
LED
Driver *
LED lamp
LED indicator
Battery
Emergency unit
190
200
42
28
180
400
400
Emergency light kit | Emergency
range
output
input
eff.
PF
surge
99355 Universal
6-60V 40-400mA 220~240V AC 86% 0.5
4 kV
Frequency
50-60 Hz
Nominal input current
40 mA (30 A inrush current with cold start)
Outout voltage (without load)
6-60V
TA Operating temperature
-25 +50 °C
Max casing temperature TC
70 °C
Control interface
Switch Line, Rest mode
Protections
Overtemperature, overload, overvoltage, short-
circuit, open circus
Charge current
200 mA
Emergency output current
400-40 mA
Emergency power
2,4W
Emergency output current
20 h
Reference norms
EN 55015 (+A1+A2), EN 61000-3-3 (+A1), EN
61000-3-2 (+A2), EN 61547 (+A1), EN60598-2-22,
EN61951-2, CEI EN 61347-1, CEI EN 61347-2-13,
CEI EN 50366
Test Switch
Emergency unit
Battery
LED indicator
Recessed installation
(Accessory included)
Switchable (on/off) in the presence of
mains via switch on SL input (switched
line). Automatic reset following battery
and/or LED lamp replacement. Electronic
multi-level charging system.
Supplied with 3,000 mAh battery pack.
The installation of the emergency kit is quick
and simple: the Emergency unit only needs to
be connected to the LED driver as shown in the
diagram.
*the driver is not included in the Emergency kit
/ the Emergency kit can be connected to all the
original drivers of the LED fixture