17
Intro
- DC
+ DC
N
L
UPS OK
CLF
INPUT:
190/305VAC 50/60Hz
186/275VDC
EXAMPLE OF POWER AND SYSTEM SIZING
THE SIZING OF THE ELECTRICAL SYSTEM SHOULD BE MADE CONSIDERING THE
FINAL POWER OF THE LED FIXTURES. THEREFORE, THERE WILL BE NO DIFFERENCE
BETWEEN A SYSTEM WITH STANDARD LAMPS (ON/OFF WITHOUT CLF) AND ONE
WITH LAMPS FEATURING CLF TECHNOLOGY. THE CLF SYSTEM CAN BE DISABLED AT
ANY TIME USING SOFTWARE, IMMEDIATELY RESTORING THE FULL POWER OF THE
LAMP. IT FOLLOWS THAT, WITH CLF INSTALLED, THE FINAL POWER NEVER EXCEEDS
THE NOMINAL POWER OF THE LAMP. IN FACT, THE LED LIGHT FIXTURE IS NEVER
OVER-POWERED, GUARANTEEING A LONG LIFE.
COMPATIBLE FIXTURES IN DIRECT CURRENT
ALL OUR LIGHT FIXTURES WITH POWER EQUAL TO OR GREATER THAN 100W AC
WORK BOTH IN ALTERNATING CURRENT (190/305VAC 50/60HZ) AND DIRECT
CURRENT (186/275VDC), THEREFORE, THEY LEND THEMSELVES WELL FOR USE AS
EMERGENCY LIGHTING IN COMPLIANCE WITH THE PREVAILING STANDARDS.
TECHNICAL
CHARACTERISTICS
STANDARD FIXTURE
ON/OFF FLAMP WITHOUT CLF
FIXTURE
FLAMP WITH CLF
INITIAL POWER
200W AC
180W AC
FINAL POWER
200W AC
200W AC
LUMINOUS FLOW
INITIAL NOMINAL (natural white LED)
29205 LM
~26451 LM
LUMINOUS FLOW
NOMINAL AFTER 90,000 HOURS
26285 LM
~26451 LM