288
N
N
L
L
L
N
L
Sw
PRI
SEC
Sw
Lin
Lout
Unswitch Switch
Test Switch
Test Switch
Emergency unit
Battery
LED indicator
Recessed installation
(Accessory included)
LED
Driver *
LED lamp
LED indicator
Battery
Emergency unit
190
200
28
180
28
28
83
150
range
output
input
eff.
PF
surge
99355
Universal
6-60V 40-400mA 220~240V AC 86% 0.5
4 kV
Frequency
50-60 Hz
Nominal input current
40 mA (30 A inrush current with cold start)
Outout voltage (without load)
6-60V
TA Operating temperature
-25 +50 °C
Max casing temperature TC
70 °C
Control interface
Switch Line, Rest mode
Protections
Overtemperature, overload, overvoltage, short-
circuit, open circus
Charge current
200 mA
Emergency output current
400-40 mA
Emergency power
2,4W
Emergency output current
20 h
Reference norms
IEC 61347-2-7:2011, IEC 61347-2-7:2011/
AMD1:2017, IEC 61347-1:2015, IEC 61347-1:2015/
AMD1:2017, EN 61347-1:2015, EN 61347-2-
7:2012+A1:2019, EN 55015:2013/A1:2015,
EN61547:2009, EN 61000-3-2: 2014
EN 61000-3-3: 2013
Emergency light kit | Emergency
Emergency
The installation of the Emergency kit is
quick and simple: the Emergency unit only
needs to be connected to the LED driver
as shown in the diagram.
*the driver is not included in the
Emergency kit/the Emergency kit can be
connected to all the original drivers of the
LED device.
Switchable (on/off) in the presence of
mains via switch on SL input (switched
line). Automatic reset following battery
and/or LED lamp replacement. Electronic
multi-level charging system.