206
INDUSTRIAL & URBAN LIGHTING
Autocontrol system
F1
600mA
F5
600mA
F2
500mA
F3
380mA
F4
250mA
morning
evening
F1
F2
F3
F4
F5
Off
20:48 h
21:47 h
01:11 h
02:56 h
04:41 h
05:35 h
17:42 h
22:10 h
01:08 h
04:06 h
07:04 h
08:34 h
20.00 h
21.00 h
22.00 h
23.00 h
24.00 h
01.00 h
02.00 h
03.00 h
04.00 h
05.00 h
06.00 h
Autonomous lamp post head
The Autocontrol system makes it so that autonomous street lights are able to automatically adjust the luminous flow based on the selected
programming depending on the technical lighting needs. The system works in combination with a timer or a twilight switch upstream of the system
which determines the daily hours of operation. Generally, the operating time is divided into 5 time slots, proportional in percentage to the duration
of the night. This time is stored by the power supply and used to determine the hours of operation in the various time slots of the following day.
Examples of operation
Dimming varies according to the season of the year and latitude of the location. Below are two examples of operation in periods of the year that
differ in number of night hours. With the Autocontrol system, a daily energy savings can be achieved that varies between 20% and 25%.
Duration time slot
30%
of Night
20%
of Night
20%
of Night
20%
of Night
10%
of Night
Off
Power exercised based
on the current used
100% =
600mA
80% =
500mA
60% =
380mA
40% =
250mA
100% =
600mA
Off
Variation of the brightness
based on the current
100%
84%
65%
46%
100%
Off
Night hours 08:47
Sunset h 20:48
Sunrise h 05:35
Night hours 08:47
Sunset h 20:48
Sunrise h 05:35