TRACK
SYSTEM
SX
DX
Aluminium body
Plan view
Axonometric view
Earthing continuity
For proper earthing of all
accessories that contribute to
form a three-phase track system,
the continuity of the earthing
line between each element is
crucial. As shown by the track
section herebeside, the position
of the earthing line (red) is
asymmetric to the central axis of
the track; based on this structural
difference one can distinguish
the right part (including the
earthing line) which binds the
introduction of all accessories.
The positioning of the earth
conductor, must be consequential
between the accessory and the
electrified track structure.
Configuration
For a correct design, we suggest
to create the structure with
top plan view, as shown in the
drawing below:
168