Door panels
Maximum permissible door panel weight
If the maximum permissible weight is exceeded, this may damage or impair the
function of the hinge.
Base area
Important!
Poor ventilation leads to damage of the appliance!
The appliance air inlet opening in the base area of the fitted kitchen must not be
covered under any circumstances.
A cross-section of at least 200 cm² must be provided for the air inlet opening.
Recess height
Number of doors
Max. permissible
door panel weight
178 cm, Vario 200
1 or 2
22 kg each
178 cm, 200 series
1
22 kg
178 cm, 200 series
2
18 kg each
140 cm, 123 cm, 82 cm, 200 series
1
14 kg
178 cm, 123 cm, 200 series wine
1
20 kg
Additional planning notes for Vario cooling and cooling appliances 200 series
Location
The appliance should be installed in a dry, well ventilated room. The location of the
appliance should not be subject to direct sunlight or near a source of heat, such as
an oven, a cooker or a radiator, etc.
If installation next to a heat source is unavoidable, observe the following minimum
distances from the heat source:
– 3 cm to electric or gas ovens,
– 3 cm to electric or gas cooker,
– 30 cm to an oil-fired or solid-fuel cooker.
Side-by-side installation
Vario 200 and 200 series cooling appliances can be installed side by side in the
following combinations, in their own kitchen units:
RW + RW
RC + RF (no other appliance next to RC model)
RW + RF (no other appliance next to RW model, except RW)
For all other combinations, a minimum clearance of 150 mm must be observed
between appliances.
Clearance to adjacent furniture depending on the furniture panel thickness
and radii
The panel thickness of customer-specific doors can be between 19 mm and 22 mm.
Dimensions of the special accessories – door panel frames.
The following diagrams show the basic dimensions of the special accessories door
front frames for RW 282 and RW 222.
The dimensions of the doors shown are designed for the following basic specifications:
– Panel thickness: 19 mm
– Gap: 3 mm
These specifications provide you with a good starting point for a variety of
kitchen designs.
Important!
The following diagrams ar not a substitute for detailed designs. Compliance with
specified requirements relating to kitchen design is essential.