A C 230 101
Gaggenau Light Bronze
Width 105 cm
Air recirculation
Special accessories
A A 200 121
3 activated charcoal filter
For air recirculation.
Can be combined with ceiling
ventilation AC 230 and AC 270.
A A 200 122
3 regenerable activated charcoal filter
For air recirculation.
Can be combined with ceiling
ventilation AC 230 and AC 270.
Installation accessories for the air
recirculation ducts you will find at the
pages 280 – 292.
Combinable with:
All the Vario 400 series and 200 serie
except with the Vario Grill
All cooktops 400 series
All cooktops 200 series
Good to know:
the hood has to be larger than
the cooktop(s).
Ceiling ventilation 200 series
A C 230
–
Perfect and harmonic integration
into the architecture of the kitchen
–
Precision crafted, solid aluminium
design
–
Energy-saving, low-noise fan
–
Rim extraction
–
Function for automatic,
sensor-controlled power adjustment
depending on the build-up of
cooking vapours
–
Easy and time saving installation
directly on the ceiling
–
Easy maintenance of the filters
–
Air recirculation
Output
Performance and noise level, output
level 3/Intensive:
Air output according to EN 61591.
Sound power level according to
EN 60704-3.
Odour reduction for air recirculation in
accordance with EN 61591.
Air recirculation:
579 / 762 m³/h.
67 / 73 dB (A) re 1 pW.
Odour reduction: > 90 %
Features
3 electronically controlled power levels
and 1 intensive mode.
Remote control is included in delivery.
Automatic function with sensor-
controlled run-on function.
Interval ventilation, 6 min.
Grease filter saturation indicator.
Activated charcoal filter saturation
indicator.
3 metal grease filters, dishwasher-safe.
3 activated charcoal filters.
The activated charcoal filter is suitable
for the preparation of fish and seafood
due to special treatment.
Protection against allergen particles
due to special treatment.
Gaggenau Light Bronze anodized
aluminium.
Fan technology with highly efficient,
brushless DC motor (BLDC).
Cooktop-based ventilation control
(with suitable cooktop).
Home network integration for digital
services (Home Connect) wireless
via WiFi.
The use of the Home Connect
functionality depends on the Home
Connect services, which are not
available in every country. For further
information please check:
home-connect.com.
Please read additional information on
Home Connect on page 416.
Planning notes
Installation directly on the ceiling.
The ceiling ventilation has to be
handled as a room ventilation when
distance to cooktop is larger than
120 cm since the direct capture of
vapours will be limited. The needed
airflow is given by an air exchange rate
of 10 to 12 times the room volume.
A suitable load-bearing substructure is
required for securing the extractor
hood. Never fit the appliance directly
onto plasterboard or similar lightweight
construction materials.
Clearance above gas appliances
min. 65 cm (more than total load gas
12 kW min. 70 cm).
Clearance above electric appliances
min. 65 cm.
Air recirculation is not recommended
in combination with Vario electric grill.
Appliance weight: approx. 41 kg.
Connection
Total connected load 140 W.
Plan a connection cable.