A L 400 121
Stainless steel
Width 120 cm
Air extraction / Air recirculation
Motorless
A L 400 191
Stainless steel
Width 90 cm
Air extraction / Air recirculation
Motorless
Necessary installation accessories
A D 754 045
Connection piece for 2 aluflex pipes
DN 150 round
Fitting AL 400, front or back side.
A D 854 043
Connecting piece for 2 flat ducts
DN 150
Fitting AL 400, bottom side.
A D 854 045
Connecting piece for 2 flat ducts
DN 150
Fitting AL 400, front or back side.
Installation accessories
A A 010 410
Air exhaust grille air recirculation
Stainless steel-coloured, 90 cm,
including installation fittings, height
adjustable.
A A 409 401
Furniture support for table ventilation
AL 400 90 cm
Can be combined with table ventilation
AL 400.
Recommended as bearer for the
worktop, instead of a cabinet frame.
A A 409 431
Furniture support for table ventilation
AL 400 120 cm
Can be combined with table ventilation
AL 400.
Recommended as bearer for the
worktop, instead of a cabinet frame.
A D 704 048
Air collector box DN 150 round pipe
2 x DN 150 round duct air intake.
To connect 1x AL 400 to AR 403 /
AR 413 or AR 401.
A D 704 049
Air collector box DN 150 flat duct
2 x DN 150 flat duct air intake.
To connect 1 x AL 400 to remote fan
AR 403/AR 413 bottom side.
Special accessories
A A 400 510
Window contact switch
Can be combined with motorless
appliances 400 series and Vario downdraft
ventilation 200 series.
Installation accessories for the air
recirculation ducts you will find at the
pages 280 – 292.
Combinable with:
All Vario cooktops 400 series
All cooktops 400 series
Cooktops 200 series
CI 2xx, CE 2xx
Good to know:
the hood can be as large as
the cooktop(s).
Table ventilation 400 series
A L 400
–
Extendable table ventilation, when
not in use can be completely
lowered into the worktop
–
Can be combined perfectly with
other Vario appliances of the
400 series
–
Dimmable, neutral white surface
LED light for ideal illumination of
the cooktop
–
Precision crafted 3 mm stainless
steel
–
For surface mounting with a visible
edge or for flush mounting
–
Motorless, can be combined with
Gaggenau BLDC remote fan units
Output
Power levels depend on the remote fan
unit, see table on page 300 – 301.
Features
3 electronically controlled power levels
and 1 intensive mode.
Interval ventilation, 6 min.
Run-on function, 6 min.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
Neutral white surface LED light
(3600 K), continuously dimmable.
Lamp output 4 x 5 W.
Illuminance 191 lx.
Spare covers for closing air outlets.
No connecting piece included.
Consumption data
Consumption data is referred to a
configuration AL 400 191 with the
remote fan unit AR 400 142.
Energy efficiency class A at a
range of energy efficiency classes
from A+++ to D.
Energy consumption 45.5 kWh/year.
Ventilation efficiency class A.
Ilumination efficiency class E.
Grease filter efficiency class C.
Sound level min. 45 dB /
max. 61 dB normal mode.
Planning notes
Refer to the table on page 296 for the
matching remote fan units for air
recirculation or air extraction mode.
Secure the control unit to the side
panel of the cabinet, not to the base of
the cabinet or the kitchen floor.
Connection to the respective
appliances via network cable.
AL 400 121 (AL 400 191)
For operation with 4 (3) Vario 200 series
cooktops, 3 (2) Vario 400 series
cooktops or a cooktop configuration
of up to 120 cm (92 cm) wide.
Operation of Vario cooking appliances
only possible without appliance cover.
Max. output of cooktops 18 kW.
Installation is possible in worktops
made of stone, synthetics or solid wood.
Heat resistance and watertight sealing
of the cut edges must be observed.
Concerning other materials please
consult the worktop manufacturer.
The remaining surface of the worktop
(min. 50 mm) between the cut-outs
must be reinforced with a support. It is
recommended to use furniture support
AA 409 401/431.
Ovens that do not exceed the maximum
allowed cabinet temperature can be
combined with the table ventilation if
built-in situation permits.
To avoid smoke when frying/grilling
refer to the manuals of VR/VP.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the power supply line
of the ventilation appliance needs a
suitable safety switch.
Please read additional planning notes
on page 228.
Connection
Total connected load 65 W
Connecting cable 1.7 m with plug.
Network cable 1.2 m.