Cut-out dimensions for appliance combinations in the 400 series. Calculator for calculating the width
of the cut-out.
Calculation of the width of the cut-out for a surface mounting
Example using a combination of VI 414, VI 422, VP 414 and 2 VL 414.
155
155
Example
Your combination
Total width of all appliances
in mm
(3x 380) + (2x 155)
1.450
……………………………………………
+ Number of connection strips
x 3 mm
4 x 3
+ 12
……………………………………………
– Lateral appliance projection
(10 mm / side)
20
– 20
– 20
(A) Total width of the cut-out
(in mm)
1.442 +/– 1
………………………………… +/– 1
Calculation of the width of the cut-out for a flush mounting
Example using a combination of VI 414, VI 422, VP 414 and 2 VL 414.
155
155
2
2
2
2
2
2
Example
Your combination
Total width of all appliances
in mm
(3x 380) + (2x 155)
1.450
……………………………………………
+ Number of connection strips
x 2 mm
4 x 2
+ 8
……………………………………………
– Lateral appliance projection
(7 mm / side)
14
– 14
– 14
(A) Total width of the cut-out
(in mm)
1.444 +/– 1
………………………………… +/– 1
+ Lateral appliance projection
(7 mm / side)
14
+ 14
+ 14
+ Silicone joint (2 mm circumference)
2 x 2
+ 4
+ 4
(B) Total width with groove
(in mm)
1.462 + 1
………………………………… 0/+ 1