Sample combinations with VL 414 ventilation element for surface mounting.
Cut-out dimensions for appliance combinations in the 400 series for Surface mounting. The technician can find the suitable cut-out
dimensions for the combinations most frequently used by referring to the previous pages and the drawings below
Cooktops
Appliances size
[mm]
Dimension B
[mm]
# of VA420010
380 / 155 / 380
901 +-1
2
380 / 155 / 380 /155
1059 +-1
3
380 / 155 / 380 / 155 / 380
1442 +-1
4
380 / 155 / 380 / 155 / 380 / 155 / 380
1983 +-1
6
380 / 155 / 380 / 380 / 155 / 380
1825 +-1
5
155 / 590 / 155
886 +-1
2
155 / 590 / 155 / 380
1269 +-1
3
380 / 155 / 590 / 155 / 380
1652 +-1
4
Recommended position for gas wok and grill
B
> 50