Planning examples for flex induction cooktop with integrated ventilation system
Planning example 1
CV 282 / CV 482 / CV 492 with unducted air recirculation
Wall installation, worktop depth 60 cm, Vertical aperture of min. 25 mm behind the backpanel of the furniture. Suggested for ideal performance are 50 mm.
Not recommended for non-thermally insulated outer wall or floor (U ≥ 0.5 W/m² °C).
Planning example 2
CV 282 / CV 482 / CV 492 with unducted air recirculation
Island installation, worktop depth 120 cm, Vertical aperture of min. 25 mm behind the back panel of the furniture. Suggested for ideal performance are 50 mm.
Not recommended for non-thermally insulated outer wall or floor (U ≥ 0.5 W/m² °C).
Planning example 3
CV 282 / CV 482 / CV 492 with ducted recirculation
Island installation, worktop depth 90 cm
Not recommended for non-thermally insulated floor (U ≥ 0.5 W/m²°C).
List of components:
— 1 x CA 082 011 Recirculation kit
List of components:
— 1 x CA 082 011 Recirculation kit
List of components:
— 1 x CA 082 071 Kit ducted air recirculation,
70 cm worktop depth
Good to know — for correct planning and installation
— For depth measurements, take account of the depth of the furniture cavity and worktop overhangs of the kitchen furniture.
— The air extraction ducting can be connected to the rear. The respective connecting pieces are available for this purpose.
— The appliance must be accessible from underneath.
Air recirculation
— Installation with air recirculation kits
— Filters can be replaced from above.
— Allow accessibility from below.
— For optimum performance, the recirculated air requires sufficient space to escape (outflow surface area of at least 440 cm²).
— The unducted recirculation set CA 082 011 requires a vertical aperture of min. 25 mm behind the backpanel of the furniture. Suggested for ideal performance are 50 mm.
All measurements in mm.
measurements in mm
900
513
122
317
490
900
99
≥ 100
≥ 100
≥ 600
223/227
167/171
Cooktops
190