www.fontini.com
95
Technical Data
1 Microswitch
2 Microswitches
Rated voltage
250 V~
Rated current
5 A
2 x 5 A
Card dimensions
5.4x8.6 cm, thickness 0.76 mm, according to ISO7816
Type of connection
Faston terminals
Ambient operating
temperature
-5 to 40°C
Thermostat
Connected thermostat
Rated voltage
100 - 240 V~
Frequency
50 - 60 Hz
Power
1.5 VA
0.55 W
Terminals
- 2 terminals (L and N) for line and neutral
- 2 C-NO relay terminals with 5 (2) A dry contact
- 2 terminals (L and N) for line and neutral
- 2 terminals for outdoor temperature sensor (Ref. 79732000)
- 2 C-NO relay terminals with 5 (2) A dry contact
Type of connection
Screw terminals
Supported cable cross-section
1 x 1,5 mm²
Systems
Heating / Air conditioning
Operating modes
Manual/Off
Automatic, Manual, Reduction, User absent,
Protection, Off, Timed manual
Set-point temperature
4°C to 40°C
Thermoregulation algorithm
ON/OFF
ON/OFF or configurable PID
Readout resolution and settings
0.1 °C
Thermal differential
0.3 °C
Adjustable via app: from 0.1 °C to 1 °C
Ambient temperature display
0°C to 40°C
Temperature display updated
Every 10 s
Reading accuracy
±0.5 °C between +15 °C and +30 °C ±0.8 °C at extremes
Protection
IP 30
External sensor
-
Maximum cable length: 10 m
Use stranded cable with minimum cross-section of 0.5 mm²
THERMOSTATS
HOTEL CARD SWITCH