121
Bea
67
BEA
kg
5kN
50Nm
H2O STOP
LED BULB VERSION:
Class A
DRR/GU5,3
A
LED BULB VERSION:
Class A
DR-PAR/GZ10
A
HALOGEN VERSION:
Class B
QR-CBC51/GU5,3
B
HALOGEN VERSION:
Class D
QRPARCBC51/GZ10
D
EU Regulation 874/2012 - Illumination equipment energy classes
.1 White
.6 Grey
.3 Anthracite
.18 Deep Brown
.4 Black
Pre-wired with
approx 250mm of
cable
Remote device
required
Protection against
impact.
IK 09 - 10,00 joule
Static load: 2000Kg
walk over
Drive over
Installation requires a
30cm water drainage
layer (gravel)
Check that diffuser’s
temperature “T max °C”
(tested at 25°C)
complies with your local
regulation
Do not install in
hollow areas
Recessed ground
fitting
Protection against
water ingress
from the cable
• Square luminaire for installation in-ground – recessed
flush with the mounting surface.
• Configuration: die cast aluminium structure, EN AB-47100
alloy (low copper content) and AISI 316L stainless steel
frame. Glass diffuser: transparent or sandblasted.
• Double layer coating for high resistance to corrosion:
the aluminium components are painted with a double
coat using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP67
• In compliance with EN 60598-1 standards
• Class of insulation: mains: I; low-voltage: III
• Installation: the luminaire is equipped with a piece of cable
with a 2-way connector for 3-conductor cables (H2O STOP)
for an easy-to-make connection. Outdoor use requires
suitable flexible cables. Installation requires a dedicated
box to be ordered separately. It is important to provide
a >300mm gravel layer or a drain system (for concrete
surface) to ensure good drainage and to avoid water
stagnation.
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
HALOGEN VERSION:
Class B
QR-CBC51/GU5,3
HALOGEN VERSION:
Class D
QRPARCBC51/GZ10
LED BULB VERSION:
Class A
DRR/GU5,3
DR-PAR/GZ10
.12 Forest Green
.0 Inox