KNX single-phase secondary
electricity meter
METERING
Description
The EK-MS2-TP-TA device has 2 independent measurement channels via external
current transformers (CT) and is suitable for measuring single-phase power lines
(230 Vac, 50-60 Hz). The flush-mounted box mounting is made in a compact case
with the possibility of mounting on a 35 mm DIN rail (EN 60715) using a special
adapter included in the supply.
Features
• Bidirectional measurement of electrical parameters for single-phase circuits
• Connection of measuring circuits to current transformers via screw terminals
• Accuracy better than 2%
• Connection to bus line via KNX terminal
• Up to 2 independent measuring circuits available
• Plastic housing
Technical data
• Supply voltage: 230 V AC
• Rated frequency fn: 50 Hz
• Current transformers from Imax 5 A up to Imax 120 A (not included in delivery)
• Current consumption from bus < 10 mA
Documentation
For more information see the technical documentation,
download from www.ekinex.com
Order information
Code
Application
Package
EK-MS2-TP-TA
KNX single-phase secondary electricity meter
1
Dimensions [mm]
Ekinex S.p.a. Via Novara, 37
28010 Vaprio d’agogna NO - Italy
CT1
PROG
CT2
KNX
EK-MS2-TP-TA
Misuratore di energia per TA est.
Energy meter for ext. CT
Made in Italy
52.80
28.55
60.70
Configuration and commissioning
By means of ETS5 software or later versions
Application program APEKME1EMUTP##.knxprod
(download from www.ekinex.com)
Power transformer for secondary
electricity meter
METERING
Description
Current transformer (CT) to be used in combination with the ekinex submeter
EK-MS2-TP-TA.
Features
• Plastic housing
• Ferrite core
• 1.5 m connecting cable with free terminals
• Openable for easy installation
Technical data
• For indoor use
• Applicable cable specifications: 10mm for EK-MST-5A,
EK-MST-20A, EK-MST-60A, 16mm for EK-MST-120A
• Nylon housing, UL94-V0 classification
• Black and white double wire
• Class 05
• Voltage level: 0.4/0.66/0.72kV
• Withstand voltage level: 2kV/1mA/1min
• Rated frequency: 50/60Hz
• Operating temperature: −40...+55°C
• Weight: 48...93g
Versions
• EK-MST-5A: Primary 0-5A / ratio 1000 to secondary (5A-5mA)
• EK-MST-20A: Primary 0-20A / ratio 1000 to secondary (20A-20mA)
• EK-MST-60A: Primary 0-60A / ratio 3000 to secondary (60A-20mA)
• EK-MST-120A: Primary 0-120A / ratio 3000 to secondary (120A-40mA)
Connections
The current transformer is equipped with a two-conductor connection cable of 1.0
m length with free terminals. The cable can not be extended.
Dimensions [mm]
•
EK-MST-5A / EK-MST-20A / EK-MST-60A
•
EK-MST-120A
Documentation
For more information see the technical documentation,
download from www.ekinex.com
Order information
Code
Application
Package
EK-MST-5A
Power transformer for secondary electricity meter
Primary 0-5A / ratio 1000 to secondary (5A-5mA)
1
EK-MST-20A
Power transformer for secondary electricity meter
Primary 0-20A / ratio 1000 to secondary (20A-20mA)
1
EK-MST-60A
Power transformer for secondary electricity meter
Primary 0-60A / ratio 3000 to secondary (60A-20mA)
1
EK-MST-120A
Power transformer for secondary electricity meter
Primary 0-120A / ratio 3000 to secondary (120A-40mA)
1
Configuration and commissioning
By means of ETS5 software or later versions
Application program APEKME1EMUTP##.knxprod
(download from www.ekinex.com)
28.5
26.5
39.8
10.2
35.5
30.8
45.6
16.0
TECHNICAL025EN
356
357
03
Introduction
17
Wall-mount devices
293
DIN-Rail mount modules
363
Visualisation
379
Audio Multiroom
427
IP Door Phone
445
Lift TV
457
Tools
461
Sales kit
466
Technical section
477
General terms of sale
481
General index