Description
The Ekinex® EK-HO1-TP module allows to manage all functions of a hotel room:
lighting, temperature control, shades and input/output indications. The device is
equipped with membrane keys for manual control and status indication LEDs; a
pushbutton allows to switch mode from automatic to manual and vice versa. The
device integrates a KNX bus communication module and is intended for mounting on
a 35 mm standard DIN-rail. It is supplied by the KNX bus; in order to be operational
it also requires a 230 Vac voltage.
Main features
• Plastic casing
• Frontal programming pushbutton and LED
• Membrane keypad with LED indication of the input status
• Pushbutton for automatic/manual mode switch
• Connection to bus line with KNX terminal block
• Screw terminal blocks for connecting inputs, outputs and 230 Vac power supply
• 3K5 climatic and 3M2 mechanic classification (according to EN 50491-2)
• Overvoltage class III (according to EN 60664-1)
• Pollution level 2 (according to IEC 60664-1)
• Mounting on 35 mm standard DIN-rail (according to EN 60715)
• 8 modular units (1 UM = 18 mm)
• Protection degree IP20 (device installed)
• Weight 595 g
Technical data
Power supply
• Load power supply 230 Vac 50/60 Hz; electrical lock 12-24 V
• Power supply (electronics) 30 Vdc via KNX bus
• Current consumption by bus < 10 mA
• Power on bus < 240 mW
Inputs
• 1 analog for NTC temperature sensor (thermostat function)
• 1 configurable as analog or digital
• 10 digital of which:
- 4 general purpose
- 2 door or window opening contact
- 1 pushbutton with pulling call for assistance/emergency
- 1 badge contact
- 2 pushbuttons «Do not disturb» e «Please make room»
Outputs
• 15 digital of which:
- 3 general purpose
- 3 for indications: «guest in the room», «room assigned», busy room or
emergency»
- 2 (paired) for blind or shade control
- 1 for courtesy light control
- 5 for fancoil: 3 for fan speed (3 speeds) and 2 for controlling electrothermal
actuators on hot/cold valves
- 1 digital room contactor and auxiliaries
• 1 powered at 12/24 Vac for controlling an electric lock
• 1 analog 0-10 V for fan speed control
Delivery
Delivery includes a terminal block for connection to the bus.
Input/output module
for hotel applications
I/O MODULES
Dimensions [mm]
144
5
25
20
20
70
90
45
BO1
BO2
S
BO5
BO6
BO3
BO7
BO10
EK-HO1-TP
Room Hotel Controller
BO4
V1
V2
V3
BO8
HEAT
COOL
BO9
L
N
bus KNX
3
4
5
6
7
8
9 10 11 12
13 14 15 16 17 18 19 20 21 22
23 24 25
1
2
26
27
28
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
BO1
BI3
BI4
BI5
BI6
BI7
BI8
BI9
COM
BI10
BI11
COM
0..10V
Com
Com
BO2
BO3
BO4
COMV
COM
V1
V2
V3
12/24 Vac
BO5
HEAT
12/24 Vac
COOL
230 Vac 50/60 Hz
BO6
BO7
BO8
BO9
BO10
Dev.
Line
Area
AI1/BI1
AI2/BI2
Configuration and commissioning
By means of ETS5 software or later versions
Application program: APEKHO1TP##.knxprod
(## = version, downloadable from www.ekinex.com)
Documentation
For more information see the technical documentation,
download from www.ekinex.com
Order information
Code
Package
EK-HO1-TP
1 pcs.
Description
The Ekinex® EK-HU1-TP module allows to manage all functions of an office or a open-
space zone: lighting, temperature control, shades and input/output indications. The
device is equipped with membrane keys for manual control and status indication
LEDs; a pushbutton allows to switch mode from automatic to manual and vice versa.
The device integrates a KNX bus communication module and is intended for mounting
on a 35 mm standard DIN-rail. It is supplied by the KNX bus; in order to be operational
it also requires a 230 Vac voltage.
Main features
• Plastic casing
• Frontal programming pushbutton and LED
• Membrane keypad with LED indication of the input status
• Pushbutton for automatic/manual mode switch
• Connection to bus line with KNX terminal block
• Screw terminal blocks for connecting inputs, outputs and 230 Vac power supply
• 3K5 climatic and 3M2 mechanic classification (according to EN 50491-2)
• Overvoltage class III (according to EN 60664-1)
• Pollution level 2 (according to IEC 60664-1)
• Mounting on 35 mm standard DIN-rail (according to EN 60715)
• 8 modular units (1 UM = 18 mm)
• Protection degree IP20 (device installed)
• Weight 595 g
Technical data
Power supply
• Load power supply 230 Vac 50/60 Hz; electrical lock 12-24 V
• Power supply (electronics) 30 Vdc via KNX bus
• Current consumption by bus < 10 mA
• Power on bus < 240 mW
Inputs
• 1 analog for NTC temperature sensor (thermostat function)
• 4 digital
Outputs
• 10 digital of which:
- 3 general purpose
- 2 (paired) for blind or shade control
- 5 fancoil: 3 for fan speed (3 speeds) and 2 for controlling electrothermal
actuators on hot/cold valves
• 1 analog 0-10V for fan speed control
Delivery
Delivery includes a terminal block for connection to the bus.
Input/output module
for office applications
I/O MODULES
Dimensions [mm]
144
5
25
20
20
70
90
45
L
N
bus KNX
3
4
5
6
7
8
9 10 11 12
23 24 25
1
2
30
31
32
33
34
35
36
37
38
39
40
41
AI1
AI2/BI2
BI3
BI4
BI5
0..10V
Com
Com
BO3
BO4
COMV
V1
V2
V3
12/24 Vac
12/24 Vac
230 Vac 50/60 Hz
L
N
bus KNX
3
4
5
6
7
8
9 10 11 12
23 24 25
1
2
AI1
AI2/BI2
BI3
BI4
BI5
0..10V
Com
Com
230 Vac 50/60 Hz
S
BO1
BO2
BO3
BO4
HEAT
COOL
V1
V2
V3
Dev.
Line
Area
50
51
52
53
HEAT
COOL
26
27
28
BO1
BO2
COM
Order information
Code
Package
EK-HU1-TP
1 pcs.
Configuration and commissioning
By means of ETS5 software or later versions
Application program: APEKHU1TP##.knxprod
(## = version, downloadable from www.ekinex.com)
Documentation
For more information see the technical documentation,
download from www.ekinex.com
TECHNICAL022EN
256
257
03
Introduction
18
Wall-mount devices
229
DIN-Rail mount modules
297
Supervision
311
Tools
315
Sales kit
321
Technical section
331
General terms of sale
335
General index