436
MCB conversion table
MCB
type
Max
current
Relative nr.
of drivers
B
25A
156%
B
20A
125%
B
16A
100%
B
10A
63%
C
25A
260%
C
20A
208%
C
16A
170%
C
10A
104%
Dip switch setting
The output current of the LED drivers can be adjusted.
This can be done using the DIP-switches on the LED driver.
Always make sure the switches are set to the correct position.
DIP-switch setting and corresponding output current can be found on the table
on the driver or on the driver instructions (http://www.doxis.be).
Driver specifications
LED Technology and efficiëncy improves rapidly. For the latest technical info please visit www.doxis.be.
LED Specifications
Brand
LED
Current
Vf min.
Vf typ.
Vf max.
Juno
Bridgelux
Vero 10
150mA
21.4V
24V
26.5V
Vesto
CREE
CXB1304
350mA
-
8.4V
-
500mA
-
8.9V
-
Titan / Tektus 45
Bridgelux
Vero 10
350mA
23V
25.5V
28V
Aster
Bridgelux
Vero 10
500mA
23.4V
25.9V
28.4V
FlatLED / Focus / Tektus 60 / Kana 350
Citizen
CLU03J
350mA
33.6V
36.2V
39.9V
Tektus 60 / Kana 500
Citizen
CLU03J
500mA
33.6V
36.2V
39.9V
Atlas
Bridgelux
Vero 18
700mA
26.1V
28.3V
30.5V
1050mA
26.8V
29V
31.2V
!!!LEDs only to be connected in series!
Air circulation
Make sure there is enough room around the spot when built in.
This room is required for air circulation (for LED cooling purposes)
Doxis advises to leave at least 20mm of free space above the spot
for optimal cooling.
min. 20mm recommended