427
The given luminous flux for Linear modules is based on the luminous flux of 4000K LED modules. For LED
modules in 3000K 95% of these values can be opted. Please apply the light output ratios in the table below for
a more accurate result.
Please keep in mind that these values apply to standard matt white texture powdercoated profiles. Depending
on the finish a luminous flux decrease up to 18% is possible relative to the luminous flux when opting for
standard matt white texture powdercoated profiles.
Light Output Ratio Profiles
Current Reduction
Light output ratios of (white) LEDliner profiles
Profile
Direct (Down)
Indirect (Up)
LEDliner35
Opal cover: 80%
-
LEDliner40
Opal cover: 62%
Grid: 70%
Opal cover: 84%
PMMA natural: 96%
LEDliner47
Opal cover: 57%
Opal cover: 63%
LEDliner65
Opal cover: 58%
Prismatic: 59%
-
LEDliner66
Opal cover: 53%
Prismatic: 55%
Opal cover: 67%
LEDliner70
Opal: 71%
Grid: 40%
Opal cover: 84%
PMMA natural: 96%
LEDliner80
Opal cover: 52%
Prismatic: 54%
Opal cover: 67%
LEDliner170
Opal cover: 69%
Prismatic: 67%
Opal cover: 71%
Current Reduction
Current Reduction
2149.00.01
The cost for current reduction will be charged once per order.
Warranty remains and is not affected
The output current of LED profiles can be reduced te obtain a
lower light output.
Depending on the configuration the minimum output can vary.
Please contact us for more information.
Measurement precision +/-10% for all flux data and 12% for efficacy data is generally to be observed for all data mentioned in this catalog. Measurement precision for CRI +/-1.5.
Measurements have been carried out with white luminaires. efficiency of drivers has been calculated with a reference efficiency of 89%.
LED Technology and efficiëncy improves rapidly. For the latest technical info please visit www.doxis.be.
The light output of a LED (strip) module decreases over time.
L - Luminous flux value: percentage of the initial luminous flux (L90 means that the
LED (strip) module will still minimally give 90% of its initial luminous flux)
The L value is related to the number of hours of operation, and is an indication for the
lifetime if the Led (strip) module.
The lifetime however is a statistical value as the lifetime may vary over the various
Led (strip) modules.
B - Below value: percentage of the Led (strip) modules are below the value;
Example:
L90B10: numbers of hours after which 10% of the Led modules are below 90% of the
initial luminous flux.
Time
Luminous
flux