182
REQUIREMENTS
LED POWER SUPPLY
DIM8
min. 50
250mA / 7W
16-29V-DC
300mA / 8W
16-29V-DC
350mA / 10W
16-29V-DC
0,90
MAINS DIMMING (FE)
21012 0258
220-240V / 50-60Hz
IP20
DIM8
min. 50
250mA / 10W
26-42V-DC
300mA / 12W
26-42V-DC
350mA / 14W
26-42V-DC
0,90
MAINS DIMMING (FE)
21012 0268
220-240V / 50-60Hz
IP20
DIM8
min. 55
500mA / 14W
15-28V-DC
700mA / 19W
15-28V-DC
0,90
MAINS DIMMING (FE)
21012 0278
220-240V / 50-60Hz
IP20
DIM8
min. 55
500mA / 26W
30-52V-DC
700mA / 36W
30-52V-DC
0,90
MAINS DIMMING (FE)
21012 0288
220-240V / 50-60Hz
IP20
DIM8
min. 48
250mA / 13W
7-44V-DC
350mA / 17W
7-44V-DC
450mA / 19W
7-44V-DC
500mA / 19W
7-40V-DC
650mA / 19W
7-30V-DC
700mA / 19W
7-28V-DC
0,90
MAINS DIMMING (FE)
21012 0298
220-240V / 50-60Hz
IP20
MULTI-POWER - IP20
23
41
122
23
41
122
30
44
138
30
44
138
38
26
140
CONSTANT CURRENT
CONSTANT CURRENT REDUCTION
FLICKER-FREE
FLICKER-FREE:
MIN DIM LEVEL OF DIMMING
DEVICE TO BE ADJUSTED FOR
FLICKR FREE DIMMING
*
*
*
*
*
*
EMERGENCY UNIT
7W / 1H
7W / 3H
166 x 46 x 34 +
135 x 45 x 23
166 x 46 x 34 +
2 x (212 x 40 x 33)
125-350mA
9-46V-DC
125-350mA
9-46V-DC
202 91 0701
202 91 0703
220-240V / 50-60 Hz
NI-Cd BATTERY 7,2V - 1,6Ah
EMERGENCY OPERATION 1h
CHARGING TIME 24h
IP20
NI-Cd BATTERY 7,2V - 4Ah
EMERGENCY OPERATION 3h
CHARGING TIME 24h
IP20
166
135
34
23
45,5
45
166
212
34
33
45,5
40
0,0
10,0
20,0
30,0
40,0
50,0
60,0
70,0
0
50
100
150
200
250
300
350
400
450
ELDN T
Vf LED
mA
DRIVER
_
+
N1
N
L1
LED INDICATOR
CHARGE
LED/LOAD
BATTERY
L
L
N
IN
OUT
REST MODE
4÷12 VDC
+
_
12
NO
+_
+
+
+
_
_
_
MAINTAINED WITH EXTERNAL ELECTRONIC DRIVER DIAGRAM
MAX. 2m DISTANCE EMERGENCY UNIT - DRIVER
Emergency units are battery powered units that come into force
in case of general power failure. In this Lighting Bible we offer
emergency units specifically for LED luminaires. Thanks to the
battery, a luminaire can keep emitting an amount of light, equal to
a percentage of the nominal value when the luminaire is emitting
at full power. This percentage is determined by the emergency unit
and is known as the Ballast-Lumen Factor (BLF). More info on this
Ballast Lumen Factor can be found on PAG TEC 16-17 based on
the type of LED.