134
DIM9
min. 84
350mA / 25W
2-74V-DC
500mA / 35W
2-72V-DC
650mA / 46W
2-72V-DC
700mA / 50W
2-72V-DC
1050mA / 60W
2-57V-DC
> 0,9
SWITCH / 1-10V / DALI DIM
300 90 63
110-240V / 50-60Hz (110V: 40W)
IP20
WD
min. 84
350mA / 25W
2-74V-DC
500mA / 35W
2-72V-DC
650mA / 46W
2-72V-DC
700mA / 50W
2-72V-DC
1050mA / 60W
2-57V-DC
> 0,9
WIRELESS DIM
21012 004W
110-240V / 50-60Hz (110V: 40W)
IP20
WD
min. 54
350mA / 18,5W
3-54V-DC
500mA / 27W
3-54V-DC
650mA / 35W
3-54V-DC
700mA / 36W
3-51V-DC
1050mA / 38W
3-36V-DC
> 0,9
WIRELESS DIM
21012 005W
220-240V / 50-60Hz
IP20
HC DIM9
min. 90
1050mA / 45W
2-44V-DC
1200mA / 52W
2-44V-DC
1400mA / 55W
2-43V-DC
> 0,9
SWITCH / 1-10V / DALI DIM
300 90 136
110-240V / 50-60Hz (110V: 40W)
IP20
HV DIM9
min. 90
350mA / 39W
20-112V-DC
500mA / 56W
2-112V-DC
650mA / 60W
2-92V-DC
700mA / 60W
2-86V-DC
> 0,9
SWITCH / 1-10V / DALI DIM
300 90 69
110-240V / 50-60Hz (110V: 40W)
IP20
MULTI-POWER
79
22
125
79
22
125
43
30
147
79
22
125
EMERGENCY UNIT
7W / 1H
7W / 3H
166 x 46 x 34 +
135 x 45 x 23
166 x 46 x 34 +
2 x (212 x 40 x 33)
125-350mA
9-46V-DC
125-350mA
9-46V-DC
202 91 0701
202 91 0703
220-240V / 50-60 Hz
NI-Cd BATTERY 7,2V - 1,6Ah
EMERGENCY OPERATION 1h
CHARGING TIME 24h
IP20
NI-Cd BATTERY 7,2V - 4Ah
EMERGENCY OPERATION 3h
CHARGING TIME 24h
IP20
166
135
34
23
45,5
45
166
212
34
33
45,5
40
0,0
10,0
20,0
30,0
40,0
50,0
60,0
70,0
0
50
100
150
200
250
300
350
400
450
ELDN T
Vf LED
mA
DRIVER
_
+
N1
N
L1
LED INDICATOR
CHARGE
LED/LOAD
BATTERY
L
L
N
IN
OUT
REST MODE
4÷12 VDC
+
_
12
NO
+_
+
+
+
_
_
_
MAINTAINED WITH EXTERNAL ELECTRONIC DRIVER DIAGRAM
MAX. 2m DISTANCE EMERGENCY UNIT - DRIVER
Emergency units are battery powered units that come into force
in case of general power failure. In this Lighting Bible we offer
emergency units specifically for LED luminaires. Thanks to the
battery, a luminaire can keep emitting an amount of light, equal to
a percentage of the nominal value when the luminaire is emitting
at full power. This percentage is determined by the emergency unit
and is known as the Ballast-Lumen Factor (BLF). More info on this
Ballast Lumen Factor can be found on PAG TEC 14-15 based on
the type of LED.
110
30
76
requirements
led power supply
technical info