CARATTERISTICHE TECNICHE
TECHNICAL CHARACTERISTICS
* Ad esclusione dell’acido fluoridrico e derivati. / Excluding hydrofluoric acid and its derivatives.
** Salvo diversa indicazione dei Codici di Posa Nazionali. La larghezza delle fughe deve comunque essere decisa dalla Direzione Lavori. / The width of grout
joints must be established by the installation supervisor, unless grout widths are regulated by national laying standards.
*** Ad eccezione delle zone caratterizzate da un maggior rischio di scivolamento (come docce pubbliche, piscine coperte, ecc.) per le quali si consiglia una
superficie SABBIATA / With the exception of areas characterized by a higher risk of slipping (such as public showers, indoor swimming pools, etc.) for which an
SABBIATA surface is recommended.
NATURALE
LAPPATA
SABBIATA
METODO DI PROVA
TEST METHOD
REQUISITI PRESCRITTI
REQUIRED VALUES
VALORI MEDI
AVERAGE VALUES
VALORI MEDI
AVERAGE VALUES
VALORI MEDI
AVERAGE VALUES
ASSORBIMENTO D’ACQUA
ISO 10545-3
≤ 0.5%
0,05%
0,05%
0,05%
WATER ABSORPTION
ASTM C 373
SFORZO DI ROTTURA (S)
ISO 10545-4
≥ 1300 N
6.080 N
6.080 N
6.080 N
BREAKING STRENGHT
ASTM C648
≥ 250 Ibf
1.364 Ibf
1.364 Ibf
1.364 Ibf
RESISTENZA ALLA FLESSIONE
ISO 10545-4
≥35 N/mm2
50 N/mm2
50 N/mm2
50 N/mm2
MODULUS OF RUPTURE
RESISTENZA ALL’ABRASIONE PROFONDA ISO 10545-6
≤ 175 mm3
143 mm3
143 mm3
143 mm3
DEEP ABRASION RESISTANCE
ASTM C 1243
DILATAZIONE TERMICA LINEARE
ISO 10545-8
Requisito non previsto
α ≤ 7 x 10-6 °C-1
α ≤ 7 x 10-6 °C-1
α ≤ 7 x 10-6 °C-1
LINEAR THERMAL EXPANSION
ASTM C 372
No provision
α ≤ 4.4 x 10-6 °F-1 / α ≤ 8 x 10-6 °C-1
α ≤ 4.4 x 10-6 °F-1 / α ≤ 8 x 10-6 °C-1
α ≤ 4.4 x 10-6 °F-1 / α ≤ 8 x 10-6 °C-1
RESISTENZA ALLE MACCHIE
ISO 10545-14
Classe/Class 3 Min.
5 RESISTENTE / RESISTANT
5 RESISTENTE / RESISTANT
5 RESISTENTE / RESISTANT
STAIN RESISTANCE
ASTM C 1378
As indicated by manufacturer
A RESISTANT
A RESISTANT
A RESISTANT
RESISTENZA ALL’ATTACCO CHIMICO*
ISO 10545-13
Come indicato dal produttore
LA-HA RESISTENTE / RESISTANT
LA-HA RESISTENTE / RESISTANT
LA-HA RESISTENTE / RESISTANT
CHEMICAL RESISTANCE*
ASTM C 650
As indicated by manufacturer
A RESISTANT
A RESISTANT
A RESISTANT
RESISTENZA AL GELO
ISO 10545-12
Nessun alterazione
No alteration
RESISTENTE/ RESISTANT
RESISTENTE/ RESISTANT
RESISTENTE/ RESISTANT
FROST RESISTANCE
ASTM C 1026
As indicated by manufacturer
RESISTANT
RESISTANT
RESISTANT
RESISTENZA ALLO SCIVOLAMENTO
DIN EN 16165 - Annex B
-
R10
-
R11
SLIP RESISTANCE
DIN EN 16165 - Annex A -
B (A+B)
-
C (A+B+C)
BCR-TORTUS
-
µ > 0,40
-
µ > 0,40
ANSI A326.3
-
ID - DCOF ≥ 0.42 (dry)
IW - DCOF ≥ 0.42 (wet)
IW+***
ID - DCOF ≥ 0.42 (dry)
IW - DCOF ≥ 0.42 (wet)
ID - DCOF ≥ 0.42 (dry)
IW - DCOF ≥ 0.42 (wet)
IW+
AS / NZS 4586
-
P3
-
P4
BS 7976-2
-
PTV 36+Wet (Sl.96)
-
PTV 36+Wet (Sl.96 - Sl. 55)
UNE 41901 EX
-
Clase 2
-
Clase 3
STONALIZZAZIONE
ANSI A137.1
Come indicato dal produttore
As indicated by manufacturer
V2
V2
V2
DESHADING
REAZIONE AL FUOCO
EN 13823
CPR (UE) 305/2011
2000/147/CE
UNI EN 13501-1
Classe / Class A1 (Wall)
Classe / Class A1 (Wall)
Classe / Class A1 (Wall)
FIRE REACTION
EN 9239-1
Classe / Class A1fl (Floor)
Classe / Class A1fl (Floor)
Classe / Class A1fl (Floor)
FLAME SPREAD
ASTM E84
-
Class A
Class A
Class A
CONDUCIBILITÀ TERMICA
EN 12524
-
α = 1,3 W/m°K / 0.7 BTU/ft h °F
α = 1,3 W/m°K / 0.7 BTU/ft h °F
α = 1,3 W/m°K / 0.7 BTU/ft h °F
THERMAL CONDUCTIVITY
FUGA MINIMA CONSIGLIATA**
RETT / RECT indoor
2 mm
2 mm
-
RECOMMENDED MINIMUM JOINT**
OUTDOOR
-
-
5-6 mm circa / approx
GRES PORCELLANATO
ISO 13006-G (Gruppo/Group BIa UGL) - EN 14411-G (Gruppo/Group BIa UGL)
ANSI A137.1 (Porcelain tile, P1 Class)
62
63