254
PROFESSIONAL LINE
I controlli che Castaldi propone sono a norma
EN 61347-2-13 e rispondono a tutte le esigenze
di installazione e di scenario.
The controls that Castaldi proposes are in
accordance with EN 61347-2-13 and meet all
installation and scenario requirements.
MASTER-PUSH, IR*
RIGOLETTO RGB MASTER
114100050013
Code /
Codice
IP 20
IP
108-216W
Power /
Potenza
3CH (RGB)
Application /
Applicazione
12-48 Vdc
Voltage /
Voltaggio
*Optional
3x3 A DMX
Imput /
Entrata
Output /
Uscita
Control for professional use, manages RGB LED strips with 12 to 24
Vdc power supply. Can be managed by button or IR remote control
(ordered separately). The multifunction inputs (push, IR) and power
and DMX outputs the make the control highly versatile, allowing it
to be used in the majority of projects. The control can manage high
power systems using the twinned Rigoletto SLAVE devices, driving
several modules via the DMX output. 12-24 Vdc power supply, max
corresponding power (auto-limiting) 3 x 36-72 W (108-216 W tot.).
Controllo per uso professionale, permette di regolare strip led
RGB con alimentazione da 12 a 24Vdc. Gestibile con pulsante o
telecomando IR (da ordinare a parte). Gli ingressi multifunzione (push,
IR) e le uscite di potenza e DMX, lo rendono altamente versatile
ed applicabile alla maggior parte dei progetti. Permette di gestire
impianti di potenza elevata, attraverso l’apparecchiatura gemella
Rigoletto SLAVE, di cui può gestire numerosi moduli attraverso l’uscita
DMX. Alimentazione 12-24 Vdc, potenza max rispettiva (autolimitata) 3
x 36-72 W (108-216 W tot).
RIGOLETTO RGB SLAVE
SLAVE-DMX
114100050023
Code /
Codice
IP 20
IP
160 W max/96 W*
320 W max/200 W*
480 W max/240 W*
Power /
Potenza
850 Lm/m
Application /
Applicazione
12-24-48 Vdc
Voltage /
Voltaggio
*Optional
3x4 A
Imput /
Entrata
Output /
Uscita
The RIGOLETTO SLAVE DMX interface is a DMX slave with 3 output
channels. Each channel is associated with a DMX address. The 3
addresses are consecutive (e.g. if channel 1 is associated with address
27, channel 2 will be associated with address 28 and channel 3 with
address 29). The outputs are implemented by PWM driver. By closing
the FLK input grounded to earth, the free flicker mode is activated
which may need to be selected when driving channels with fixing
magnets. The slave address is selected by the dip switch with 1-9 lever.
The encoding is binary. The dip switch 1 has weight 1, dip switch 2 has
weight 2, and dip 3 has weight 4. The addresses range from 1 to 512. In
the left column some examples of configuration: in the first case being
selected only dip 3 the address goes to value 4; in the second case by
selecting 1, 2, 4 the address goes to value 11; while in the third and last
case with 4, 6, 7 goes to value 104. With the dip switch 10 (MODE) in
the ON position the 8-bit standard mode is selected while in the OFF
position the 16 bit City Design mode is selected. The 16-bit mode is
compatible only with products by City Design. To download the full list
of addresses, visit the Castaldi website.
L’interfaccia RIGOLETTO SLAVE DMX è uno slave DMX con 3 canali di
uscita. Ogni canale è associato ad un indirizzo DMX. I 3 indirizzi sono
consecutivi (se il canale 1 è associato per esempio all’indirizzo 27, il
canale 2 sarà associato all’indirizzo 28 e il canale 3 all’indirizzo 29). Le
uscite vengono attuate tramite pilotaggio PWM. Chiudendo a massa
l’ingresso FLK viene attivata la modalità flicker free che può essere
necessario selezionare in caso di pilotaggio di profili con magneti di
fissaggio. L’indirizzo dello slave viene selezionato tramite i dip switch
a levetta 1-9. La codifica è binaria. Il dip switch 1 ha peso 1, il dip
switch 2 ha peso 2, il dip 3 ha peso 4. Gli indirizzi variano da 1 a 512.
Nella colonna a sinistra alcuni esempi di configurazione: nel primo
caso essendo selezionato solo il dip 3 l’indirizzo assume il valore 4;
nel secondo caso selezionando 1, 2, 4 l’indirizzo ha valore 11; mentre
nel terzo e ultimo caso con 4, 6, 7 ha valore 104. Con il dip switch
10 (MODE) in posizione ON si seleziona la modalità 8 bit standard
mentre in posizione OFF si seleziona la modalità 16 bit City Design.
La modalità 16 bit è compatibile solo con prodotti by City Design. Per
scaricare la lista completa degli indirizzi visitare il sito di Castaldi.