57
For further informa� on, please visit / Per ulteriori informazioni visita www.castaldiligh� ng.it
D30 BOXER
outdoor - esterni
STANDARD
aluminium grey
BASE
AL
grigio alluminio
VARIANT
graphite sa� n � nish
VARIANTE
GR
gra� te sa� nato
0,8m
boxer/36LW-MB LED
Code
Codice
System Power
Potenza Sistema
Source
Sorgente
K
Output flux
Flusso uscente
D30/36LWN-MB-AL
84,5W
LED
4000K
5908 lm
D30/36LWW-MB-AL
84,5W
LED
3000K
5286 lm
Photometric data reference:
Fotometria di riferimento:
500
1000
1500
2000
90°
60°
30°
cd/klm
γ=0.0 α=β=37°
Emed(lx)
1633
408
181
102
65
h (m)
2.00
4.00
6.00
8.00
10.00
Ø (m)
1.38
2.75
4.13
5.51
6.89
D30/36LWN-MB-AL
Medium beam
Fascio medio
0,8m
boxer/36LW-RA LED
Code
Codice
System Power
Potenza Sistema
Source
Sorgente
K
Output flux
Flusso uscente
D30/36LWN-RA-AL
84,5W
LED
4000K
5384 lm
D30/36LWW-RA-AL
84,5W
LED
3000K
4893 lm
Photometric data reference:
Fotometria di riferimento:
90
180
270
360
450
90°
60°
30°
cd/klm
5
15
30 20
isolux distribu�on on ground height 6m
distribuzione isolux al suolo h 6m
12m
8
4
0
4
20
16
12
8
4
0
4
8
12
16
20m
10
2
D30/36LWN-RA-AL
Road asymmetric
Stradale asimmmetrico
D30 boxer
SPOT LIGHTS,
WALL MOUNTED,
POLE MOUNTED,
PROIETTORI, PARETE,
APPLICAZIONI SU PALO,
Safety tempered glass diffusers.
Vetri di sicurezza temperati.
Note: 5000K on request.
DALI version on request.
Nota: A richiesta 5000K.
A richiesta versione DALI.
140
285
508
166
445
0,8m
boxer/36LW-NB LED
Code
Codice
System Power
Potenza Sistema
Source
Sorgente
K
Output flux
Flusso uscente
D30/36LWN-NB-AL
84,5W
LED
4000K
6723 lm
D30/36LWW-NB-AL
84,5W
LED
3000K
6032 lm
Photometric data reference:
Fotometria di riferimento:
6000
12000
18000
24000
90°
60°
30°
cd/klm
γ=0.0 α=β=9°
Emed(lx)
5530
1382
614
346
221
h (m)
4.00
8.00
12.00
16.00
20.00
Ø (m)
0.63
1.27
1.90
2.53
3.17
D30/36LWN-NB-AL
Narrow beam
Fascio stretto
0,8m
boxer/36LW-SB LED
Code
Codice
System Power
Potenza Sistema
Source
Sorgente
K
Output flux
Flusso uscente
D30/36LWN-SB-AL
84,5W
LED
4000K
5942 lm
D30/36LWW-SB-AL
84,5W
LED
3000K
5355 lm
Photometric data reference:
Fotometria di riferimento:
1000
2000
3000
4000
90°
60°
30°
cd/klm
γ=0.0 α=β=22°
Emed(lx)
4015
1004
446
251
161
h (m)
2.00
4.00
6.00
8.00
10.00
Ø (m)
1.77
3.53
5.30
7.06
8.83
D30/36LWN-SB-AL
Spot beam
Fascio spot
Optional accessories
Accessori opzionali
• To see page 58