595
CONTATORI CONTO
Contatori di energia
schemi di collegamento
N1
L
N2
LOAD
LINE
CONTO D2-b
I N P U T
O U T P U T
L
N
LOAD
+
–
2
7
SO
6
4
1
L
N
LOAD
3
20
SO
21
6
4
1
+
–
I N P U T
O U T P U T
CONTO D1
Conto D4-Pt MID
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
5
8
11
2
MBUS
A
B
T1 / T2
12 / 24V d.c.
1 C
E
Conto D4-Pd MID
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
MBUS
A
B
T1 / T2
12 / 24V d.c.
1 C
E
Conto D2
INPUT
LOAD
N
MBUS
A
B
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
5
8
11
2
RS485
+
–
SG
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
INPUT
LOAD
N
RS485
+
–
SG
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
INPUT
LOAD
N
OUTPUT
INPUT
12 / 24V d.c.
max 30V 50mA
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
RS485
+
–
SG
T1 / T2
12 / 24V d.c.
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
OUTPUT
INPUT
12 / 24V d.c.
1 C
E
max 30V 50mA
CONTO D2
Conto D4-Pt MID
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
5
8
11
2
MBUS
A
B
T1 / T2
12 / 24V d.c.
1 C
E
Conto D4-Pd MID
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
MBUS
A
B
T1 / T2
12 / 24V d.c.
1 C
E
Conto D2
INPUT
LOAD
N
MBUS
A
B
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
5
8
11
2
RS485
+
–
SG
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
INPUT
LOAD
N
RS485
+
–
SG
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
INPUT
LOAD
N
OUTPUT
INPUT
12 / 24V d.c.
max 30V 50mA
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
RS485
+
–
SG
T1 / T2
12 / 24V d.c.
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
OUTPUT
INPUT
12 / 24V d.c.
1 C
E
max 30V 50mA
CONTO D4-Pd
Conto D4-Pt MID
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
5
8
11
2
MBUS
A
B
T1 / T2
12 / 24V d.c.
1 C
E
Conto D4-Pd MID
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
MBUS
A
B
T1 / T2
12 / 24V d.c.
1 C
E
Conto D2
INPUT
LOAD
N
MBUS
A
B
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
5
8
11
2
RS485
+
–
SG
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
INPUT
LOAD
N
RS485
+
–
SG
T1 / T2 (INPUT)
12 / 24V d.c.
1 C
E
INPUT
LOAD
N
OUTPUT
INPUT
12 / 24V d.c.
max 30V 50mA
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
RS485
+
–
SG
T1 / T2
12 / 24V d.c.
1 C
E
L1
L2
L3
N
INPUT
LOAD
3
4
6
7
9
1
11
OUTPUT
INPUT
12 / 24V d.c.
1 C
E
max 30V 50mA
CONTO D4-Pt
X
X
X
L1
L2
L3
N
X
X X
LOAD
I N P U T
O U T P U T
D T
+
–
SG
1
3
4
6
7
9
1
C
11
CONTO D6-Pd
USCITE
IMPULSI ENERGIA S0 EN/IEC 62053-31
Tipo
Optorelè libero da potenziale
Portata contatti
27Vdc/ac – 50mA
Energia associata
Energia attiva
Positiva o negativa (versioni MID)
Peso impulso
selezionabile 1Wh/varh÷10kWh/kvarh
Durata impulso
selezionabile 50÷500ms
RS485
Protocollo
Modbus RTU
Standard
RS485-3-fili
Impedenza
120 Ohm (programmabile da menù)
Velocità trasmissione
selezionabile 4800÷38400 bit/s
M-BUS
Protocollo
M-BUS
Standard
EN13757
Velocità trasmissione
selezionabile 300÷9600 bit/s
USCITE
RS485
CONTO D1
CONTO D1 MID
Protocollo
Modbus RTU
-
Standard
RS485-3-fili
-
Velocità trasmissione
selezionabile
1200÷9600 bit/s
-
IMPULSI ENERGIA S0 EN/IEC 62053-31
Tipo
Optorelè libero da potenziale
Portata contatti
12÷27Vdc-10÷27mA
Energia associata
Energia attiva
Peso impulso
1 imp/Wh
Durata impulso
700ms
70ms
*Per il dimensionamento termico dei quadri
** kTA*kTV
Massima visualizzazione
1...9
9999999,99kWh/kvarh
10...99
99999999,9kWh/kvarh
100...999
999999999kWh/kvarh
1000...9999
9999999,99MWh/MTarh
10000...99999
99999999,9MWh/MTarh
≥100000
999999999MWh/MTarh