12
Model plans
BORA S Pure
see more model plans at https://partner.bora.com
Installation may only be carried out in accordance with the applicable standards, regulations and laws.
PURSA - exhaust air model for kitchen units
MP_7006 - with air flow towards the back, round
Planning instructions
1 Atleast50 mmfromfrontedgeto
cut-out.Theminimumdistanceof
50mmfromthefrontedgeofthe
worktoptotheworktopcut-outisa
recommendationfromBORA.
Forthebindingmeasurement,please
contactyourworktopmanufacturer.
2 Spacerequirementsfortechnology
3 CoreboreholeatleastØ 180 mm
Mustexpelairinastraightline
regardlessoftheweatherconditions
BORA product
1 PURSASPureinductioncooktopwith
integratedcooktopextractor–
exhaustair
BORA Ecotube product
1 EFV/1ductconnection,shallow
1 EFBV90/190°bend,shallowvertical
1 UEBR/13boxwallsleeve,round
1 EF750/1shallowduct750 mm
1 ERV/1ductconnection,round
1 EFR90/190°transition,
shallowround
1 ER750/1roundduct750 mm
Sealing material is included in the
scope of delivery in the case of
moulded parts with a socket design
PURSA - exhaust air model for kitchen units
MP_7112 - with air flow towards the back in the plinth
Planning instructions
1 Atleast50 mmfromfrontedgeto
cut-out.Theminimumdistanceof
50mmfromthefrontedgeofthe
worktoptotheworktopcut-outisa
recommendationfromBORA.
Forthebindingmeasurement,please
contactyourworktopmanufacturer.
2 Spacerequirementsfortechnology
3 Wallopening310x155mm.
71 mmfrombottomedgeofopening
tocentreofduct.Mustexpelair
inastraightlineregardlessofthe
weatherconditions
BORA product
1 PURSASPureInductioncooktopwith
integratedcooktopextractor–
exhaustair
BORA Ecotube product
1 EFV/1ductconnection,shallow
2 EFBV90/190°bend,shallowvertical
2 EFBH90/190°bend,shallow
horizontal
1 UEBF/13boxwallsleeve
2 EF750/1shallowduct750mm
Sealing material is included in the
scope of delivery in the case of
moulded parts with a socket design