A
B
A
B
C
A
B
C
Transformers
Safety transformers in accordance with EN 61558/VDE 0570 Parts 2 - 6
Version encapsulated in cast resin · Safety class II · Protection class IP 65
When choosing the transformer, make sure that the connected load does not exceed the
specified output in VA. The connected load results from the luminaire type, number of units
and power losses.
Transformers may only be operated outside the water.
Distribution box made of stainless steel for installation in floors or walls
Protection class IP 67 · Safety class III
Stainless steel · Material No. 1.4301 · electropolished
4 screw cable glands
1 hose connection for soft PVC protective hose Ø 28 x 3.5 mm
After installation, the distribution box must be sealed with a sealing compound!
B
A
C
A
B
C
71 039
Inrush current limiter for DIN rail mounting
37 110
62
Limits the starting current of electronic ballasts and LED drivers to 33.9 A for 300 ms, an
acceptable value for circuit protection.
Inrush current limiter for DIN rail mounting
Output
Secondary
A
B
C
70 427
Transformer 230/11.5 V ·
50 VA
1 x 50 VA
55
155
50
70 478
Transformer 230/11.5 V · 105 VA
1 x 100 VA
55
215
50
Output
Secondary
A
B
C
70 479
Transformer 230/11.5 V · 200 VA
2 x 100 VA
135 125
90
70 484
Transformer 230/11.5 V · 300 VA
1 x300 VA
135 140
90
70 488
Transformer 230/11.5 V · 400 VA
2 x 200 VA
180 155 110
70 497
Transformer 230/11.5 V · 600 VA
2 x 300 VA
180 175 110
A
B
70 223
Distribution box
120 x120
95
Transformers for low-voltage luminaires
Accessories for swimming pool luminaires
555
Kat33_BG47_48_553-576_GB_FR.indd
555
28.04.17
10:41