¯E
lx
88606
1 HIT-CE 35 W
m
120
240
360
480
600
7
5
3
1
9
4
2
0
2
4
¯E
lx
88715
1 HIT-DE-CE 70 W
1 HST-DE 70 W
m
400
800 1200 1600 2000
14
10
6
2
18
4
2
0
2
4
¯E
lx
88616
1 HIT-DE-CE 150 W
1 HST-DE 150 W
m
400
800 1200 1600 2000
14
10
6
2
18
4
2
0
2
4
m
40
80
120
160
200
7
5
3
1
9
4
2
0
2
4
¯E
lx
77816
LED
lx
77818
LED
m
80
160
240
320
400
7
5
3
1
9
4
2
0
2
4
¯E
¯E
lx
88607
1 HIT-CE 35 W
Ι max. bei γ 25°
m
80
160
240
320
400
7
5
3
1
9
4
2
0
2
4
¯E
lx
88618
1 HIT-DE-CE 150 W
1 HST-DE 150 W
m
160
320
480
640
800
14
10
6
2
18
8
4
0
4
8
Ι max. bei γ 15°
¯E
lx
88716
1 HIT-DE-CE 70 W
1 HST-DE 70 W
m
200
400
600
800 1000
14
10
6
2
18
8
4
0
4
8
Ι max. bei γ 15°
¯E
lx
77850
LED
m
60
120
180
240
300
2
3
4
1
2
1
0
1
2
Ι max. bei γ 25°
¯E
lx
77851
LED
m
40
80
120
160
200
3
5
7
9
1
4
2
0
2
4
Ι max. bei γ 23°
¯E
lx
88654
1 HIT-TC-CE 35 W
m
300
600
900 1200 1500
7
5
3
1
9
4
2
0
2
4
¯E
lx
88753
1 HIT-TC-CE 35 W
m
200
400
600
800 1000
7
5
3
1
9
8
4
0
4
8
¯E
lx
88756
1 HIT-TC-CE 70 W
m
160
320
480
640
800
14
10
6
2
18
8
4
0
4
8
An extensive and efficient series of in-ground luminaires for use both indoors and out. A large number
of different light outputs as location luminaires, symmetrical, asymmetrical and adjustable floodlights are
available for planning work.
These luminaires stand out thanks to their particularly high pressure load of 5000 kg.
Extremely sturdy design for areas with a high pressure load.
The luminaires are mounted in a recessed housing made of high-strength cast aluminium on a foundation
that absorbs the pressure loads, and can be driven over by vehicles with pneumatic tyres. The luminaires
must not be used in areas where they are exposed to horizontal loads caused by braking, accelerating and
changes of direction.
The foundation, including drainage, must be laid by the customer.
Please note: The operating temperatures T specified in the table (according to EN 60598, ambient
temperature ta 15 °C) are reached in the centre of the glass surface.
When the glass is wet, there may be a risk of slipping. For walkable public areas, we recommend skid-
blocking glass in accordance with DIN 51130 R 13. With the additional specification R after the article
number, we can supply all luminaires with skid-blocking glass. This increases the dispersion of the light
distribution.
Trim ring made of stainless steel · Safety glass · Luminaire housing and recessed housing made of cast
aluminium · Floodlights with reflectors made of pure anodised aluminium · 88756 with cold light reflector
1.8 m connecting cable with water stop
Accessories for symmetrical / asymmetrical floodlights:
Inside louvres
Infrared filter for reducing the temperature of the glass surface by approx. 20 %
Combinations of louvres and infrared filters can be supplied as custom-made products.
Accessories for adjustable floodlights:
Diffuser disks, wide beam or flat beam Inside louvres
The accessories may be combined or used individually.
As accessories for luminaires 88 753 · 88 654 · 88 756, we can supply colour effect filters in the colours
green 70 321 · blue 70 322 · yellow 70 323. Accessories must be ordered separately.
On request, the LED luminaires are available in the light colours green, blue, amber and red.
The LED luminaires on this page will impress you through the choice of colour temperature, a minimum
LED service life of 50 000 hours and 20 years availability guarantee for the LED modules.
LED colour temperature: 4000 K article number or 3000 K article number + K3
The luminaire luminous flux and the luminaire connected wattage quoted in the table might change as a
result of technical progress. On our website you will find data sheets with information on each luminaire
concerning not only the current values but also the LED service life and the luminous flux in relation to the
respective colour temperature.
Drive-over in-ground luminaires
For installation situations with high pressure load
Location luminaires or floodlights
230
Kat33_BG19_20_217-240_GB_FR.indd
230
14.03.17