BugSaver
®
Luminaires with BEGA BugSaver ® technology can be switched
from 3000 Kelvin to amber light. That is where our designated
BEGA BugSaver® control devices or a conventional DALI light
control come into play.
You can choose from three BEGA BugSaver ® control devices
for switching the colour temperature with simultaneous output
reduction. Control can be effected via control phase or with
the help of virtual midnight calculation for up to nine connected
luminaires. No other components will be needed.
Luminaires with our BEGA BugSaver ® technology can be
controlled via DALI Device Type 8 (DT8) and can therefore
be easily integrated into intelligent control systems.
These ensure a needs-oriented and eco-friendly use of
lighting systems:
• Output reduction or switch-off at night
• Use of motion and/or dusk sensors
3000 K
Amber
18:00
18:00
24:00
12:00
6:00
100 %
output
Reduction
to 70 %
Change the colour temperature
to create light for people and the
environment
h
19