Specifications for Naiade 55 and Naiade 90 power supply
Naiade 90
Naiade 55
Number of fixtures which can be installed according to:
• Power
• Cable section
• Line length
• Max surge supported by the ballasts: 2kV.
• Working temperature of the ballasts: -35°C + 50°C.
• The ballasts must not be directly exposed to UV-rays.
• When calculating sections/lengths, all the fixtures are supposed to be supplied with power at the line end.
• The IP67 connector supplied with the fixtures is suitable for sections from 1.5 to 4 mm2.
• Insulation class II. Earthing is not required.
Line length
Cable
1,5 mm2
Cable
2,5 mm2
Cable
4 mm2
25W 24Vdc
10 m
13
13
13
25W 24Vdc
50 m
13
13
13
25W 24Vdc
100 m
13
13
13
25W 24Vdc
150 m
12
12
13
25W 24Vdc
200 m
11
12
13
60W 24Vdc
10 m
33
33
33
60W 24Vdc
50 m
31
32
33
60W 24Vdc
100 m
27
30
31
60W 24Vdc
150 m
23
27
30
60W 24Vdc
200 m
19
25
29
90W 24Vdc
10 m
49
50
50
90W 24Vdc
50 m
43
46
48
90W 24Vdc
100 m
35
42
46
90W 24Vdc
150 m
26
37
42
90W 24Vdc
200 m
19
31
39
T409996
T409998
T409999
Code
Power
Line length
Cable
1,5 mm2
Cable
2,5 mm2
Cable
4 mm2
25W 24Vdc
10 m
5
5
5
25W 24Vdc
50 m
5
5
5
25W 24Vdc
100 m
4
5
5
25W 24Vdc
150 m
4
4
5
25W 24Vdc
200 m
4
4
4
60W 24Vdc
10 m
12
12
12
60W 24Vdc
50 m
12
12
12
60W 24Vdc
100 m
10
11
12
60W 24Vdc
150 m
8
10
11
60W 24Vdc
200 m
7
9
11
90W 24Vdc
10 m
18
18
18
90W 24Vdc
50 m
16
17
18
90W 24Vdc
100 m
13
16
17
90W 24Vdc
150 m
9
14
16
90W 24Vdc
200 m
7
12
15
T409996
T409998
T409999
Code
Power
Cable
273