69
67
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
A++
A+
A
Tapioca
TAPIOCA
kg
H2O STOP
EU Regulation 874/2012 - Illumination equipment energy classes
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
.8 Anodized
Aluminium
• Square or round luminaire – for installation in wall, ceiling
or ground – recessed.
• Configuration: die-cast aluminium structure, EN AB-47100
alloy (low copper content). Anodized aluminium frame – only
round. Glass diffuser: transparent or sandblasted, fixed to
the aluminium body through a robotic gluing system.
• Double layer coating for high resistance to corrosion: the
aluminium components are painted with a double coat
using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP67
• In compliance with EN 60598-1 standards
• Class of insulation: III
• Installation: the luminaire is equipped with a piece of cable
for an easy-to-make connection and an H2O STOP device.
Tapioca 24V is equipped with a dc/dc highly efficient
resin-coated converter that removes electromagnetic
interference and allows parallel wiring. The luminaire is
protected against polarity reversal and sudden voltage
peak. Installation requires a dedicated box to be ordered
separately. It is important to provide a �200mm gravel layer
or a drain system (for concrete surface) to ensure good
drainage and to avoid water stagnation.
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
Installation requires
a 20cm water drai-
nage layer (gravel).
Recessed wall fitting
Pre-wired with approx
200mm of cable
Remote device required
Protection against
impact.
IK 08 - 5,00 joule
IK 06 - 1,00 joule�
�(only version � 55 mm)
Static load: 500Kg walk over
(version without frame)
Static load: 2000Kg walk over
(version with frame)
Installation in
concrete ceiling:
box for installation
required
Recessed ground fitting
Do not install in
hollow areas
Protection against
water ingress
from the cable
(not for RGB versions)
Glass surface temperature
<70�C