57
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
A++
A+
A
67
K12
K12
kg
H2O STOP
EU Regulation 874/2012 - Illumination equipment energy classes
LED VERSION:
Class A/A+/A++
Luminaire supplied
with integrated LED modules
that cannot be replaced
• Square luminaire for installation in wall and ground –
recessed.
• Configuration: die-cast aluminium structure, EN AB-47100
alloy (low copper content). Glass diffuser fixed to the
aluminium body through a robotic gluing system.
• Double layer coating for high resistance to corrosion:
the aluminium components are painted with a double
coat using powders which are compliant with QUALICOAT
standards: a first layer of epoxy powder (with excellent
chemical and mechanical resistance) and a second
finishing layer of polyester powder (resistant to UV rays
and atmospheric agents). The entire painting process of the
aluminium fitting starts from components which have been
sandblasted in advance to make the surface more porous
and increase the adherence of the paint. Ares effects
alkaline and acid washing to clean the surfaces completely,
then rinses with demineralised water to remove any residue
particles, subsequently a chemical conversion treatment is
done to protect against rusting.
• Protection rating: IP67
• In compliance with EN 60598-1 standards
• Class of insulation: III
• Installation: the luminaire is equipped with 300mm of
cable for a quick connection. K12 Power LED is equipped
with a dc/dc highly efficient converter that removes
electromagnetic interference and allows parallel wiring.
The whole range is protected against polarity reversal and
sudden voltage peak. Outdoor use requires suitable flexible
cables. Installation requires a dedicated box to be ordered
separately. It is important to provide a >200mm gravel layer
or a drain system (for concrete surface) to ensure good
drainage and to avoid water stagnation.
• We recommend the use of a connection system with a
protection degree greater than or equal to the protection
degree of the luminaire.
• During the installation and the maintenance of the fixtures
it is important to be careful and avoid damages on the paint
coating.
Damages on the coating exposed to outdoor conditions or
water, could cause corrosion.
Chemical substances affect the anticorrosion covering
protection.
Static load:
1500Kg
walk over
Protection against
impact.
IK 10 - 20,00 joule
Pre-wired with approx
300mm of cable.
Remote device
required.
Installation requires
a 20cm water drai-
nage layer (gravel).
Glass surface temperature
<70°C
Do not install in
hollow areas
Recessed ground
fitting
Recessed wall fitting
Protection against
water ingress
from the cable
(not for RGB versions)